Low temperature evaporators are mostly integrated structures that do not require complex civil engineering. Before entering the site, the five supporting conditions of site, power supply, pipeline, auxiliary gas source, and safety protection are mainly implemented. Heat pump models generally do not require external steam heat sources.
1、 Venue and environmental conditions
Installation location: Priority indoor ventilation area, rain and sun protection; Outdoor installation requires rain shelters and anti freezing insulation for pipelines. The recommended ambient temperature is 5-38 ℃, as extreme high and low temperatures can affect the heat transfer efficiency of the heat pump.
Ground and load-bearing: The ground is flat and hardened; Small equipment can be installed on the ground of ordinary factory buildings, while large tonnage models need to calculate the floor load and pour the equipment foundation if necessary.
Maintenance and Access: Reserve a maintenance space of ≥ 0.8-1.2m around the equipment for easy disassembly and assembly of heat exchangers, CIP maintenance, and replacement of seals; Reserve lifting and handling channels to accommodate the entry of the entire machine.
Anti seepage cofferdam: It is recommended to install an anti-seepage cofferdam and collection tank to prevent the leakage of the original liquid and concentrated liquid, and meet the requirements of environmental protection verification.
2、 Power supply supporting facilities
The standard is 380V 50Hz three-phase five wire system, and the installed power is selected according to the processing capacity, ranging from several kilowatts to hundreds of kilowatts; An independent distribution cabinet is required, equipped with air switches and grounding protection; Explosion proof models are equipped with electrical systems according to explosion-proof specifications.
Tip: Confirm the remaining capacity of transformers in the factory area in the early stage to avoid insufficient capacity.
3、 Pipeline water supply and drainage matching
Raw liquid feeding pipe: a pipeline for feeding wastewater to be treated, equipped with valves and filter interfaces;
Condensed water discharge pipe: The condensed water flows out by itself and can be connected back to the pool or pipe;
Concentrated liquid discharge outlet: connected to a sealed anti-seepage storage tank, and the hazardous waste concentrated liquid is collected in a sealed manner;
Cleaning water interface: tap water/pure water interface, used for CIP online cleaning;
Cooling water pipe (as needed): The air-cooled heat pump model does not require cooling water; Water cooled models require supporting cooling water supply and return.
4、 Auxiliary air source: Compressed air (required for most models)
Pressure of 0.5-0.7MPa, required to be dry, oil-free, and free of impurities; Used for pneumatic valves, defoaming injection, and auxiliary blowing of vacuum systems; Small models do not require pneumatic valve configuration.
5、 Waste gas, safety and other supporting facilities
Non condensable gas emissions: Negative pressure closed operation, a small amount of non condensable waste gas, connected to waste gas collection according to environmental impact assessment requirements; The working conditions containing volatile solvents must be accompanied by exhaust gas treatment.
Fire protection and lighting: comply with workshop fire safety regulations, and the area is equipped with sufficient lighting.
Tank matching: original liquid storage tank, concentrated liquid temporary storage tank, cleaning agent tank, matched with liquid level and mixing as needed.
Automatic control signal docking: supports linkage with customer sewage station PLC, and can reserve signal interfaces.
6、 Supplementary explanation
The modular equipment has been integrated with the host, heat exchange, vacuum, pump unit, and CIP circuit before leaving the factory; We can provide a detailed list of interfaces, loads, and distribution parameters based on the on-site drawings, and we can also conduct on-site surveys and provide layout plans.